    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

low lubricity oval gear flow900 measurement

Date:2018-01-03 source:

  low lubricity oval gear flow900 measurement   email: porter@microflowmeter.com

Shanghai JSN Micro Flow MeterCO.,LTD is a manufactory integrating scientific research, production, sales andservice. It is located in the Shanghai Industrial Zone. The company is based onthe people-oriented principle and takes the program as the degree. Competitive,product covers a variety of materials and super micro liquid flow meter,ovalgear flow meter ,mass flow meter.spur gear flow meter,gear pump,gear meteringpump etc instrumentation instrument. Widely applicable to trade settlement andmeasurement in various industries such as petroleum, chemical, environmentalprotection, metallurgy, electric power, transportation, food, medicine,military industry, scientific research, etc.

 low lubricity oval gear flow900 measurement

low lubricity oval gear flow900 measurement

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

SinceMay 23, 2011, Shanghai Jinshen Instrument Co., Ltd. successfully released a newoval gear flow meter CX-M and G series, the liquid flowmeter range than thefirst in China reached more than 1: 100, and at the same time to ensureaccuracy 0.5% above the flowmeter industry model.From this since the base meterhas been a pioneer in flowmeter technology, but also one of the high-endflowmeter brand.The perfect technical level, excellent quality standards,innovation has been innovation Wells said. Deep base flow meter has been toprovide customers with a reliable use of the experience in the past rely on theimport of the era, the customer has been a headache for after-sales service,and base deep flow meter with 8 years of use of the long life, in one fellswoop cracked this situation.



low lubricity oval gear flow900 measurement

The CX-M and G series gearflow meters consist of a flow transmitter and a display. The oval gear flowmeter metering chamber of the flow transmitter has a pair of elliptical orcircular measuring gears. The gears and the measuring chamber form severalknown volumes. The cavity acts as a metering unit. Under the influence of thedifferential pressure between the inlet and outlet, the gear is driven torotate, and the imported liquid is continuously metered into the outlet aftermeasuring the metering chamber. At the same time, the sensor generates acorresponding electrical signal and sends it to the display section. Afterpartial treatment, the instantaneous flow and cumulative flow of the liquid canbe displayed.

 low lubricity oval gear flow900 measurement

low lubricity oval gear flow900 measurement


Item

model

K-factor

The minimum flow

Flow range

Connection size

Gear flow meter

CX-G0.025-P-AL

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.025-P-SS

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.04-P-AL

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.04-P-SS

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.1-P-AL

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.1-P-SS

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.2-P-AL

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.2-P-SS

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.4-P-AL

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G0.4-P-SS

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G1-P-AL

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G1-P-SS

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G2-P-AL

2ml

0.04L/Min

0.5-60L/min

G3/4

gear flow meter

CX-G2-P-SS

2ml

0.04L/Min

0.5-60L/min

G3/4

Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized


What are the precautions for the gear flow meter?

1) If the medium temperature is too high, or the pressure is too high, please inform us before purchasing, we can customize it for you.

2) When the pipeline is continuously operated and the flowmeter is to be installed in a horizontal pipeline, a bypass pipeline should be installed to facilitate cleaning and overhaul; when the flowmeter is installed on a vertical pipeline, the flowmeter should be installed on the bypass. In the pipeline, to prevent debris from falling into the instrument. When the fluid flows from bottom to top, the vertical tube in the upper part of the flowmeter should be as short as possible to reduce the precipitation of impurities in the upper piping.